Material Hub > Materialien

Victrex plc (Datenlieferant)

VICTREX Pipes™ (Polyetheretherketone)

VICTREX Pipes™ are durable, lightweight pipe and tube extruded from VICTREX® PEEK polymer which offer high temperature performance and a unique combination of properties. An excellent alternative to metals, VICTREX Pipes provide chemical and corrosion resistance, low permeability, wear abrasion and impact resistance in a polymer-based pipe and tube.

Weitere Informationen zum Beispiel zu Abrieb finden Sie hier.

Abbildung des Materials
Anwendungsgebiete Oil and Gas; Industrial; Aerospace
alternative Namen
  • Abkürzung: PEEK
weitere Angaben
  • Extreme temperature range
  • Aggressive chemical and corrosion resistance
  • Excellent wear and abrasion performance
  • High permeation resistance
  • Stable mechanical properties at high temperatures
  • Lightweight combined with excellent mechanical properties
  • Fatigue performance
  • Low smoke and toxicity
  • Ductile behaviour

Physikalische Eigenschaften

Name Wert Bemerkung Messverfahren und -bedingungen
Abmessung (Durchmesser) 6 – 200 nm outer diameter
Dichte 1.3 g/cm³ Specific Gravity ISO 1183, Crystalline
Dicke 0.8 – 5 mm wall thicknesses depending on outer diameter
Wasseraufnahme 0.07 % ISO 62-1, 24 hrs, 23°C
Mechanische Eigenschaften
 
Rockwell-Härte (M) 99 HRM ASTM D785
Zug-Elastizitätsmodul 3.5 GPa ISO 527, 23°C
Zugdehnung beim Bruch 45 % ISO 527, Break, 23°C
Zugfestigkeit 100 MPa ISO 527, Yield, 23°C
Thermische Eigenschaften
 
Einsatztemperatur 240 °C Mechanical w/o impact
180 °C Mechanical w/ impact
Glasübergangstemperatur 143 °C ISO 11357
linearer Längenausdehnungskoeffizient 47 10⁻⁶/K ASTM D696, Below Tg
108 10⁻⁶/K ASTM D696, Above Tg
Schmelztemperatur 343 °C ISO 11357

Chemische Eigenschaften

Name Wert Messverfahren und -bedingungen
chemische Beständigkeit Ammonia Liquid: No Attack (200°C)
Acetic Acid (Conc): No Attack (200°C)
Benzene: No Attack (100°C)
Brake Fluid (Mineral / Polyglycol): No Attack (200°C)
Ethylene Glycol (50% aqueous): No Attack (200°C)
Hydrochloric Acid (10%): No Attack (100°C)
Hydrogen Sulfide (Gas): No Attack (200°C)
Heavy Aromatic Naptha (100%): Slight Attack (200°C)
Jet A Fuel: No Attack (23°C)
Methanol: No Attack (100°C)
Motor Oil: No Attack (200°C)
Petroleum Oils: No Attack (100°C)
Sea Water: No Attack (200°C)
Skydrol Hydraulic Fluid: No Attack (23°C)
Sodium Bisulphite (50% aqueous): Slight Attack (200°C)
Sodium Hydroxide (50%): No Attack (200°C)

Freigaben

Regularium Land Bauteil Bemerkungen Gültig bis Prüfzeugnis
FDA (CFR Title 21)
RoHS (Richtlinie 2011/65/EU)
3-A Sanitary
GADSL
EC61249-2-21 inherently halogen-free
BSE/TSE
EMEA/410/01 Rev 2
ISO 9001

Daten bereitgestellt von

Haftungsausschluss

Victrex plc and/or its group companies (“Victrex plc”) believes that the information contained in this document is an accurate description of the typical characteristics and/or uses of the product or products, but it is the customer’s responsibility to thoroughly test the product in each specific application to determine its performance, efficacy, and safety for each end-use product, device or other application. Suggestions of uses should not be taken as inducements to infringe any particular patent. The information and data contained herein are based on information we believe reliable. Mention of a product in this document is not a guarantee of availability. Victrex plc reserves the right to modify products, specifications and/or packaging as part of a continuous program of product development. Victrex plc makes no warranties, express or implied, including, without limitation, a warranty of fitness for a particular purpose or of intellectual property non-infringement, including, but not limited to patent non-infringement, which are expressly disclaimed, whether express or implied, in fact or by law. Further, Victrex plc makes no warranty to your customers or agents, and has not authorized anyone to make any representation or warranty other than as provided above. Victrex plc shall in no event be liable for any general, indirect, special, consequential, punitive, incidental or similar damages, including without limitation, damages for harm to business, lost profits or lost savings, even if Victrex has been advised of the possibility of such damages regardless of the form of action. VICTREX™, APTIV™, VICOTE™, VICTREX PIPES™, VICTREX HT™, VICTREX ST™, VICTREX WG™, PEEK-ESD™ and the Triangle (Device), are trademarks of Victrex plc or its group companies.

Ähnliche Materialien

Wählen Sie die Materialeigenschaften aus, anhand derer ähnliche Materialien identifiziert werden sollen. Durch Hinzufügen weiterer Eigenschaften sowie Anpassen der jeweiligen Abweichung lässt sich die Ergebnisliste beeinflussen. Hier wird eine Auswahl der ähnlichsten Materialien angezeigt. Um die gesamte Liste zu erhalten, drücken Sie auf die Schaltfläche "Vollständige Ergebnisliste anzeigen".

5%

Letzte Aktualisierung: 06.07.2023
Feedback

Geben Sie uns gern Feedback zum Material Hub.

Kontaktformular

Fragebogen zur Gebrauchstauglichkeit

QR Code