PERTEC® UP FKM 70.501-07 (Fluorine elastomer)
Symbolbild
- Abkürzung: FKM
Physikalische Eigenschaften
Name | Wert | Bemerkung | Messverfahren und -bedingungen |
---|---|---|---|
Dichte | 1.89 – 1.95 g/cm³ | ISO 1183-1 | |
Änderung des Volumens | 0.2 % | ISO 1817, Medium: IRM 901 Oil (ASTM 1), 70 h, 150 °C | |
0.8 % | ISO 1817, Medium: IRM 902 Oil (ASTM 2), 70 h, 150 °C | ||
1.8 % | ISO 1817, Medium: IRM 903 Oil (ASTM 3), 70 h, 150 °C | ||
3.2 % | ISO 1817, Medium: ASTM Fuel C, 70 h, 23 °C | ||
23 % | ISO 1817, Medium: ASTM FAM B , 168 h, 23 °C | ||
Mechanische Eigenschaften | |||
Druckverformungsrest | 35 % | ISO 815-1B, 22 h, 150 °C, 25 % deformation | |
28 % | ISO 815-1A, 22 h, 200 °C, 25 % deformation | ||
Shore-Härte (A) | 65 – 75 Shore A | ASTM D 412 | |
Zugdehnung beim Bruch | 316 % | ASTM D 412 | |
Zugfestigkeit | 20.2 MPa | ASTM D 412 | |
Änderung der Härte | 6 Points | ISO 188, Medium: Air, 168 h, 225 °C | |
-0.5 Points | ISO 1817, Medium: IRM 901 Oil (ASTM 1), 70 h, 150 °C | ||
-0.5 Points | ISO 1817, Medium: IRM 902 Oil (ASTM 2), 70 h, 150 °C | ||
-1.5 Points | ISO 1817, Medium: IRM 903 Oil (ASTM 3), 70 h, 150 °C | ||
-3 Points | ISO 1817, Medium: ASTM Fuel C, 70 h, 23 °C | ||
-18 Points | ISO 1817, Medium: ASTM FAM B, 168 h, 23 °C | ||
Änderung der Zugdehnung beim Bruch | -15 % | ISO 188, Medium: Air, 168 h, 225 °C | |
0.3 % | ISO 1817, Medium: IRM 901 Oil (ASTM 1), 70 h, 150 °C | ||
1 % | ISO 1817, Medium: IRM 902 Oil (ASTM 2), 70 h, 150 °C | ||
1.5 % | ISO 1817, Medium: IRM 903 Oil (ASTM 3), 70 h, 150 °C | ||
-20 % | ISO 1817, Medium: ASTM FAM B, 168 h, 23 °C | ||
Änderung Zugfestigkeit | -19 % | ISO 188, Medium: Air, 168 h, 225 °C | |
1 % | ISO 1817, Medium: IRM 901 Oil (ASTM 1), 70 h, 150 °C | ||
-2.6 % | ISO 1817, Medium: IRM 902 Oil (ASTM 2), 70 h, 150 °C | ||
-6.3 % | ISO 1817, Medium: IRM 903 Oil (ASTM 3), 70 h, 150 °C | ||
-48 % | ISO 1817, Medium: ASTM FAM B, 168 h, 23 °C | ||
Thermische Eigenschaften | |||
Einsatztemperatur | -20 – 200 °C | approximate value, dependent of the application | |
Glasübergangstemperatur | -17 °C | ASTM E1356-08 | |
Kältesprödigkeitstemperatur bei Schlagbeanspruchung | -30 °C | ASTM D 2137-A | |
TR10 | -16.5 °C | ASTM D 1329 |
Chemische Eigenschaften
Name | Wert | Messverfahren und -bedingungen |
---|---|---|
Vernetzungsart | peroxid |
Freigaben
Regularium | Land | Bauteil | Bemerkungen | Gültig bis | Prüfzeugnis |
---|---|---|---|---|---|
3-A Sanitary Standard Number 18-03 Class I | konform | ||||
ADI free | konform | ||||
BAM approved maximum temperature 150 °C, maximum oxygen pressure 30 bar | konform | ||||
BfR XXI (Natural and synthetic rubber) Category 4 | konform | ||||
D.M. 21/03/1973 (Migration test only) | konform | ||||
Dlgs. 25.01.1992 n.108 Art.2 Parte D | konform | ||||
DVGW W 270 | konform | ||||
EC 1935/2004 (excl. article 15) | konform | ||||
FDA - CFR 21 - 177.2600 food a) - f) | konform | ||||
French Arrete 09/11/1994 (Migration test) | konform | ||||
GB 4806.11-2016 | konform | ||||
KIWA NSF/ANSI 51 formulation | konform | ||||
LFGB § 30/31 | konform | ||||
SR 817.023.21 | konform | ||||
Tested and qualified by BNIC (Bureau National Interprofessionnel du Cognac) | konform | ||||
UBA Guideline for elastomeric materials in contact with drinking water for cold and hot water up to 85 °C | konform | ||||
PAH Category 1 (AfPS GS 2019:01) | konform | ||||
PAHs requirements according Regulation (EU) No 1272/2013 | konform | ||||
Phthalate free | konform |
Hersteller
Angst+Pfister GmbH
Christian Geubert
+491779730874
Anfrage per E-Mail
Webseite | Mehr Details | Zu den Materialien von Angst+Pfister GmbH
Daten bereitgestellt von
Angst+Pfister GmbH
Christian Geubert
+491779730874
Anfrage per E-Mail
Webseite | Mehr Details | Zu den Materialien von Angst+Pfister GmbH
This information is based on our available data. These values are measured on standard test specimens and are within the normal tolerance range of material properties and do not represent guaranteed property values. Therefore they shall not be used for specification purposes. The customer is solely responsible for quality and suitability of material for his application. He has to test usage and processing prior to use. Angst+Pfister makes no guarantees for the suitability of the material for any given application and assumes no obligation or liability in connection with the information provided above.
Ähnliche Materialien
Wählen Sie die Materialeigenschaften aus, anhand derer ähnliche Materialien identifiziert werden sollen. Durch Hinzufügen weiterer Eigenschaften sowie Anpassen der jeweiligen Abweichung lässt sich die Ergebnisliste beeinflussen. Hier wird eine Auswahl der ähnlichsten Materialien angezeigt. Um die gesamte Liste zu erhalten, drücken Sie auf die Schaltfläche "Vollständige Ergebnisliste anzeigen".