PERTEC® CIP FKM 75.501-04 (Fluorine elastomer)
symbolic image
- abbreviation: FKM
Physical Properties
Name | Value | Method and conditions |
---|---|---|
change of volume | 2 % | ASTM D 471, Medium: IRM 903 Oil (ASTM 3), 70 h, 150 °C |
5 % | ASTM D 471, Medium: ASTM Fuel C, 70 h, 40 °C | |
14 % | ASTM D 471, Medium: M15, 70 h, 40 °C | |
3.5 % | ASTM D 471, Medium: ATF DEXTRON, 168 h, 150 °C | |
density | 1.96 – 2 g/cm³ | ASTM D 297 |
Mechanical properties | ||
change of hardness | 1 Points | ASTM D 573, Medium: Air, 70 h, 200 °C |
-1 Points | ASTM D 573, Medium: Air, 70 h, 250 °C | |
-1 Points | ASTM D 471, Medium: IRM 903 Oil (ASTM 3), 70 h, 150 °C | |
-4 Points | ASTM D 471, Medium: ASTM Fuel C, 70 h, 40 °C | |
-9 Points | ASTM D 471, Medium: M15, 70 h, 40 °C | |
-2 Points | ASTM D 471, Medium: ATF DEXTRON, 168 h, 150 °C | |
change of tensile strain at break | -5.5 % | ASTM D 573, Medium: Air, 70 h, 200 °C |
10 % | ASTM D 573, Medium: Air, 70 h, 250 °C | |
2.5 % | ASTM D 471, Medium: IRM 903 Oil (ASTM 3), 70 h, 150 °C | |
-21 % | ASTM D 471, Medium: ATF DEXTRON, 168 h, 150 °C | |
change of tensile strength | 4.5 % | ASTM D 573, Medium: Air, 70 h, 200 °C |
-18 % | ASTM D 573, Medium: Air, 70 h, 250 °C | |
-3.5 % | ASTM D 471, Medium: IRM 903 Oil (ASTM 3), 70 h, 150 °C | |
-16 % | ASTM D 471, Medium: ATF DEXTRON, 168 h, 150 °C | |
compression set | 17 % | ASTM D 395-B2, 70 h, 150 °C |
16 % | ASTM D 395-B2, 22 h, 200 °C | |
Shore hardness (type A) | 70 – 80 Shore A | ASTM D 2240 |
tensile strain at break | 370 % | ASTM D 412 |
tensile strength | 23 MPa | ASTM D 412 |
Thermal properties | ||
application temperature | -15 – 200 °C | |
glass transition temperature | -7 °C | VDA 675 115/116 |
TR10 | -8 °C | ASTM D 1329 |
Chemical Properties
Name | Value | Method and conditions |
---|---|---|
cross linking | peroxid |
Certificates
Regulation | Country | Part | Remark | Valid until | Certificate |
---|---|---|---|---|---|
3-A Sanitary Standard Number 18-03 Class I | konform | ||||
ADI free | konform | ||||
BfR XXI (Natural and synthetic rubber) Category 4 | konform | ||||
D.M. 21/03/1973 (Migration test only) | konform | ||||
Dlgs. 25.01.1992 n.108 Art.2 Parte D | konform | ||||
EC 1935/2004 (excl. article 15) | konform | ||||
FDA - CFR 21 - 177.2600 food a) - f) | konform | ||||
French Arrete 09/11/1994 (Migration test) | konform | ||||
GB 4806.11-2016 | konform | ||||
KIWA NSF/ANSI 51 formulation | konform | ||||
LFGB § 30/31 | konform | ||||
SR 817.023.21 | konform | ||||
Tested and qualified by BNIC (Bureau National Interprofessionnel du Cognac) | konform | ||||
USP Class VI Chapter <87> (In Vitro) | konform | ||||
USP Class VI Chapter <88> (In Vivo) -121 °C | konform | ||||
PAH Category 1 (AfPS GS 2019:01) | konform | ||||
PAHs requirements according Regulation (EU) No 1272/2013 | konform | ||||
Phthalate free | konform |
Producer
Angst+Pfister GmbH
Christian Geubert
+491779730874
Request via e-mail
Website | Further details | Show the materials of Angst+Pfister GmbH
Data Provided by
Angst+Pfister GmbH
Christian Geubert
+491779730874
Request via e-mail
Website | Further details | Show the materials of Angst+Pfister GmbH
This information is based on our available data. These values are measured on standard test specimens and are within the normal tolerance range of material properties and do not represent guaranteed property values. Therefore they shall not be used for specification purposes. The customer is solely responsible for quality and suitability of material for his application. He has to test usage and processing prior to use. Angst+Pfister makes no guarantees for the suitability of the material for any given application and assumes no obligation or liability in connection with the information provided above.
Similar Materials
Select the material properties on the basis of which similar materials are to be identified. By adding further properties as well as adjusting the respective deviation, the result list can be influenced. A selection of the most similar materials is displayed here. To get the full list, press the "Show all results" button.